January 20, 2021

CORTINAS ATIRANTADAS PDF

Verificación de carga en cortinas ancladas ubicadas en áreas de riesgo em tirantes de cortinas ancoradas executadas para eliminação de risco .. “Análise numérica do comportamento de cortinas atirantadas em solos”. More, J. Z. P. Análise Numérica do Comportamento de Cortinas Atirantadas em Solos 0DVWHUV ‘LVVHUWDWLRQ – Departamento de Engenharia Civil. Larissa Roedel’s 4 research works with reads, including: Manifestações Patológicas decorrentes em Solo Grampeado e Cortina Atirantada. Larissa.

Author: Shara Faull
Country: Libya
Language: English (Spanish)
Genre: Personal Growth
Published (Last): 16 May 2015
Pages: 72
PDF File Size: 7.62 Mb
ePub File Size: 11.19 Mb
ISBN: 309-5-71660-374-1
Downloads: 40773
Price: Free* [*Free Regsitration Required]
Uploader: Mazuzahn

Portuguese term or phrase: Material properties of the anchored curtain. After the modeling was performed using the Plaxis 8.

The method employs prestressed rods and anchors to support the terrain. Figure 1 shows landslide susceptibility maps for four communities in the city of Rio de Janeiro. The loads on the tie rods in reinforced concrete structures of the hillside containment structures located in the city of Rio de Janeiro need to be evaluated. Figure 6 Displacement of the anchored curtain after 50 years Plaxis.

Another important consideration in the case analysis is that it is hard to obtain information regarding the informal properties located uphill from the anchored curtains or their residents, either due to high resident turnover or the construction dynamics of the houses.

In the modeling carried out cirtinas the 20 anchored curtains, the soil behavior was investigated in relation to the shear strength, its plastification at the time of the execution of the structure, and its projection after 50 years of service life.

You can request verification for cprtinas languages by completing a simple application that takes only a couple of minutes. It is a potential condition under which an accident atirantadsa occur. Table 1 atirantavas the geotechnical parameters used in the numerical modeling of the soil layers and earthwork for each anchored curtain.

Landslides in the hills of the city of Rio de Janeiro are a cyclical phenomenon that lead to enormous economic and social damage that includes road blockages and the destruction of common types of houses, resulting in homelessness and in many cases loss of life. Table 2 Material properties of the anchored curtain. In this case, the axial stiffness AS and the bending stiffness BS are determined by equations 34 and 5where is the modulus of elasticity, and t is the thickness of the curtain.

The anchoring bulb is modeled using one element per meter having only axial stiffness, which is denominated in Plaxis as a “geogrid”. Landslide susceptibilities in hazardous areas.

Between the free section and the ground, the mobilized shear stress is ignored, and spring elements are used corfinas connect the curtain to the anchor bulb. Finite element modeling involves the definition and manipulation of the geometry and specifications of the material and stirantadas properties, generation of the finite element mesh, and definition of the loads and displacements that will be applied to the component.

  ATTACHMENT IN PSYCHOTHERAPY DAVID WALLIN PDF

Hazards, however, represent the possibility or probability of some damage atkrantadas a population people, physical structures, and production systems or to a segment of a population.

cortina atirantada | Portuguese to English | Construction / Civil Engineering

Load check on anchored curtains located in geotechnical hazard areas in the city of Rio de Janeiro. Sanitary sewage and leachates originating from uncollected garbage enter the soil contained by the anchored curtains and directly infiltrate the curtain walls. Elizabeth Sabido Maldonado, Km. cortinae

On the other hand, the theoretical tests, i. It is atlrantadas to know, evaluate, and classify the degree of aggressiveness of the environment and to know the concrete and geometry of the structure, thus establishing the correspondence between both, i.

The base supports are fixed, and the lateral supports are movable to allow for lateral displacements. The execution of anchored curtains, although old, is among the most modern containment methods.

Soil strains or displacements see Figure 6which can occur between the anchor lines in the direction normal to atiranradas plane of the problem, atirantaas ignored corrtinas the two-dimensional situation.

The graph in Figure 8 shows blue line the maximum RLVT results for all of the 20 anchored curtains surveyed over a period of 5 years. The conclusion is that the Plaxis 8. For the plastified region of the soil, on the other hand, a rigid plastic model with resistance parameters such as cohesion and angle of friction of the soil, which are related to its stability and rupture, would be used.

Their main characteristic is the absence of adequate technical standards, often without surrounding urbanization and without important public services such as sanitary sewage and household waste collection.

This is due to the fact that the curtain has three rows of tie rods, which impart a smaller variation on the forces on the soil structure. If they excessively develop over time, these cracks will allow the entry of aggressive agents from the sanitary sewage originating from the informal constructions uphill from the containment structures executed in poor communities, which will attack the reinforcement and concrete structure.

Four basic procedures are employed for solving geotechnical engineering problems using the finite element method: The calculation of the stiffness matrix, an interpolation function, allows relating the value of the variable of the problem to be solved in the nodes of each element with its geometry and property, generating a system of dortinas in matrix form.

According to Lopesthe finite element method FEM is the most commonly used numerical method employed in geotechnical civil engineering due to its ease in dealing with heterogeneous, nonlinear nonlinear elasticity fortinas plasticity and time dependent viscosity and densification problems.

Initially, the analysis of the structural behaviors of the 20 anchored curtains executed in the city of Rio de Janeiro was developed considering the effects of the overload stresses due to the additional forces at the end of the project service life, which was estimated to be 50 years, as established in standard EN The discretization of the continuous medium occurs when it is divided by imaginary lines and surfaces that result in a finite number of two-dimensional elements that, for this research, was verified to be sufficient for the analysis.

  GLADIATOR SIMON SCARROW PDF

In addition to the practical tests used to evaluate the load behaviors of the tie rods over time, theoretical tests of the rods were carried out using the Plaxis computational tool, which allows simulations of increases in overload due to increases in residential and other buildings uphill from the anchored curtain occurring throughout the years.

Figure 3 Schematic representation of the finite element analysis Tschiptschin, The city of Rio de Janeiro, which is known for both the tragedies caused by landslides on its slopes and the terrain formed by the encounter of the ocean with the mountains, has built more than eleven thousand interventions on hillsides located at different sites in the municipality over the past 50 years.

cortina atirantada

Figure 2 An anchored curtain in a geotechnical hazard area Author. In the first phase, the continuous medium or domain of the problem is divided into sub-domains called finite elements that are connected by a finite number of nodal points or, more simply, nodes.

Because the modeling is two-dimensional, soil deformations occurring between the anchor atirantadaas perpendicular to the presented model are completely ignored. Portuguese PRO pts in category: The properties of the materials were input so that the model can be as close as possible to the actual situation for cortinss of the studied cases. Over the years, the word has become synonymous with an abject housing reality. Return to KudoZ list. With increasing overloads over time, a second plastification occurs in the lower part of the panel of the anchored curtain, with a small change in the plastification zones of the contained soil.

Over time, these anchored curtain hillside containment structures suffer increases in overload from the contained soil, which was not foreseen in the design, due to the increase in informal constructions in uphill areas with high geological-geotechnical risks and where most of the curtains in the scope of this analysis are located. Care must be observed with issues such as data entry, specification of soil and material parameters, spacing of cortjnas tie rods, and the distribution of the forces applied to the tie rods in this measurement.

Anchored corttinas hillside containment structures are reinforced concrete structures that have estimated service lives of 50 years. Login to enter a peer comment or grade.